Revision as of 14:49, 24 November 2006 editFklatt (talk | contribs)935 editsNo edit summary← Previous edit | Revision as of 10:21, 17 December 2006 edit undoRamskjell (talk | contribs)256 edits Merge + CleanupNext edit → | ||
Line 1: | Line 1: | ||
{{merge|DFIG}} | |||
{{cleanup|December 2006}} | |||
'''Doubly-fed ''electric machines''''' (i.e., ]s or ]s) belong to a category of electric machines that incorporate two multiphase winding sets of similar power rating that have independent means of excitation. An electronic controller conditions bi-directional, speed synchronized, and multiphase electrical power to at least one of the winding sets. The sum of the power ratings of the multiphase winding sets determine the total electro-mechanical conversion power rating of the machine. As a result, doubly-fed electric machines are synchronous electric machines by nature with both winding sets actively participating in the energy conversion process (i.e., doubly-fed). Uniquely, doubly-fed electric machines can operate at constant torque to twice synchronous speed for a given frequency of excitation with each active winding set rated at half the total power of the machine (i.e., contiguous operation between sub-synchronous through super-synchronous speed range). Theoretically, the electronic controller is comparably less expensive, more efficient, and more compact than electronic controllers of other electric machine because only the power of the rotating (or moving) active winding set is controlled, which is half the total power output (or less) of the electric machine. However, Doubly-Fed Electric Machines are very sensitive to the synchronous relationship between speed and excitation frequency and as a result, are susceptible to instability without introducing extraordinary means of control. Like any synchronous machine, losing synchronism will result in alternating torque pulsation and other related consequences. The ], the ], and the so-called ] are the only examples of doubly-fed electric machines. Like all synchronous electric machines or any state-of-art efficient electric machines, including the brushless DC or Permanent Magnet electric machines, doubly-red electric machines require electronic control for practical operation and should be considered an electric machine system or more appropriately, an adjustable speed drive. Although sometimes described as doubly-fed electric machines, the wound-rotor induction machine (slip-energy recovery) and the field-excited synchronous machine are singly-fed electric machines because only one winding set actively participates in the energy conversion process. All electric machines are categorized as either ]s or Doubly-Fed Electric Machines. | '''Doubly-fed ''electric machines''''' (i.e., ]s or ]s) belong to a category of electric machines that incorporate two multiphase winding sets of similar power rating that have independent means of excitation. An electronic controller conditions bi-directional, speed synchronized, and multiphase electrical power to at least one of the winding sets. The sum of the power ratings of the multiphase winding sets determine the total electro-mechanical conversion power rating of the machine. As a result, doubly-fed electric machines are synchronous electric machines by nature with both winding sets actively participating in the energy conversion process (i.e., doubly-fed). Uniquely, doubly-fed electric machines can operate at constant torque to twice synchronous speed for a given frequency of excitation with each active winding set rated at half the total power of the machine (i.e., contiguous operation between sub-synchronous through super-synchronous speed range). Theoretically, the electronic controller is comparably less expensive, more efficient, and more compact than electronic controllers of other electric machine because only the power of the rotating (or moving) active winding set is controlled, which is half the total power output (or less) of the electric machine. However, Doubly-Fed Electric Machines are very sensitive to the synchronous relationship between speed and excitation frequency and as a result, are susceptible to instability without introducing extraordinary means of control. Like any synchronous machine, losing synchronism will result in alternating torque pulsation and other related consequences. The ], the ], and the so-called ] are the only examples of doubly-fed electric machines. Like all synchronous electric machines or any state-of-art efficient electric machines, including the brushless DC or Permanent Magnet electric machines, doubly-red electric machines require electronic control for practical operation and should be considered an electric machine system or more appropriately, an adjustable speed drive. Although sometimes described as doubly-fed electric machines, the wound-rotor induction machine (slip-energy recovery) and the field-excited synchronous machine are singly-fed electric machines because only one winding set actively participates in the energy conversion process. All electric machines are categorized as either ]s or Doubly-Fed Electric Machines. | ||
] 00:05, 15 November 2006 (UTC) | ] 00:05, 15 November 2006 (UTC) |
Revision as of 10:21, 17 December 2006
It has been suggested that this article be merged with DFIG. (Discuss) |
You must add a |reason=
parameter to this Cleanup template – replace it with {{Cleanup|December 2006|reason=<Fill reason here>}}
, or remove the Cleanup template.
Doubly-fed electric machines (i.e., electric motors or electric generators) belong to a category of electric machines that incorporate two multiphase winding sets of similar power rating that have independent means of excitation. An electronic controller conditions bi-directional, speed synchronized, and multiphase electrical power to at least one of the winding sets. The sum of the power ratings of the multiphase winding sets determine the total electro-mechanical conversion power rating of the machine. As a result, doubly-fed electric machines are synchronous electric machines by nature with both winding sets actively participating in the energy conversion process (i.e., doubly-fed). Uniquely, doubly-fed electric machines can operate at constant torque to twice synchronous speed for a given frequency of excitation with each active winding set rated at half the total power of the machine (i.e., contiguous operation between sub-synchronous through super-synchronous speed range). Theoretically, the electronic controller is comparably less expensive, more efficient, and more compact than electronic controllers of other electric machine because only the power of the rotating (or moving) active winding set is controlled, which is half the total power output (or less) of the electric machine. However, Doubly-Fed Electric Machines are very sensitive to the synchronous relationship between speed and excitation frequency and as a result, are susceptible to instability without introducing extraordinary means of control. Like any synchronous machine, losing synchronism will result in alternating torque pulsation and other related consequences. The Wound-Rotor Doubly-Fed Electric Machines, the Brushless Wound-Rotor Doubly-Fed Electric Machine, and the so-called Brushless Doubly-Fed Electric Machines are the only examples of doubly-fed electric machines. Like all synchronous electric machines or any state-of-art efficient electric machines, including the brushless DC or Permanent Magnet electric machines, doubly-red electric machines require electronic control for practical operation and should be considered an electric machine system or more appropriately, an adjustable speed drive. Although sometimes described as doubly-fed electric machines, the wound-rotor induction machine (slip-energy recovery) and the field-excited synchronous machine are singly-fed electric machines because only one winding set actively participates in the energy conversion process. All electric machines are categorized as either Singly-Fed Electric Machines or Doubly-Fed Electric Machines. Fklatt 00:05, 15 November 2006 (UTC)
Categories: