Misplaced Pages

Distortionmeter

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.
A measuring device used in electronics
This article needs additional citations for verification. Please help improve this article by adding citations to reliable sources. Unsourced material may be challenged and removed.
Find sources: "Distortionmeter" – news · newspapers · books · scholar · JSTOR (September 2024) (Learn how and when to remove this message)

A distortionmeter (or more precisely distortion factor meter) is an electronic measuring instrument which displays the amount of distortion added to the original signal by an electronic circuit.

Harmonic distortion

Harmonic distortion is equivalent to adding harmonics to a signal. When a purely sinusoidal signal is in this way, a series of harmonics is superimposed on the original signal, and can be detected with suitable equipment.

If the input is

f i = a 1 s i n ( ω t ) {\displaystyle {f_{i}}=a_{1}\cdot sin(\omega t)}

The normalized output is

f o = a 1 s i n ( ω t ) + a 2 s i n ( 2 ω t ) + a 3 s i n ( 3 ω t ) + . . {\displaystyle {f_{o}}=a_{1}\cdot sin(\omega t)+a_{2}\cdot sin(2\omega t)+a_{3}\cdot sin(3\omega t)+..}

The value of Total Harmonics Distortion (THD) is defined as the ratio of the harmonics to the fundamental; i.e.,

T H D = a 2 2 + a 3 2 + . . a 1 {\displaystyle THD={\frac {\sqrt {{a_{2}}^{2}+{a_{3}}^{2}+..}}{a_{1}}}}

This ratio can be given in dB or in percentage.

The instrument

A distortionmeter is a level meter with two switchable parallel circuits at the input. The first circuit measures the total signal at the output of a system. (For low distortion levels this will be almost equal to fundamental). That value is adjusted to read 100% or, equivalently, to 0 dB. The second circuit is a high pass filter which removes (as much as practical) the fundamental frequency. This can be a notch filter, one which passes all but the fundamental, with negligible attenuation at other frequencies (including whatever harmonics might be present). Alternatively, if the distortion products are at higher frequencies, a highpass filter can be used if its cutoff rate is sufficiently steep to not affect the expected distortion products. The output of the filter is measured as a percentage of the fundamental, and the reported value will be the distortion value.

See also

References

  1. Reference data for Radio Engineers, Howard W.Sams & co.ITT, ISBN 0-672-21218-8, p.18-12
Analog television broadcasting topics
Systems
Color systems
Video
Sound
Modulation
Transmission
Frequencies & bands
Propagation
Testing
Artifacts
Electrical and electronic measuring equipment
Metering
Analysis
Generation
Categories: